Capacitance |
|
| |
Capacitance
is measured at 120HZ,less than 1.0 volts rms, at 25≧ Capacitance
increases with increasing temperature. |
|
 |
|
|
 |
DC leakage
current (DCL)
|
|
|
|
DC leakage
current is the current that ,after a five minute charging period ,
flows through a capacitor when voltage is measured at 25≧ with full
rated DC voltage applied to the capacitor through a 1000 ohm
resistor in series with the capacitor. DC current increases with
increasing temperature. |
|
 |
|
|
 |
Dissipation factor
( DF)
|
|
|
|
Dissipation
factor is measured at 120HZ up to 1.0 volt rms maximum. DF increases
with increasing frequency. |
|
 |
|
|
 |
Temperature
stability
|
|
|
|
Step
NO.
|
TEMP. |
CAPACITANCE
|
DCL
|
DF |
|
1 |
+25≧
|
Within specified
tolerance |
Within original
limit |
Within original
limit |
|
2
|
-55≧
|
Within \10%
initial value |
N/A
|
Within original
limit |
|
3 |
+25≧
|
Within \5%
initial value |
Within original
limit |
Within original
limit |
|
4
|
+85≧
|
Within \10%
initial value |
Within10X original
limit |
See table 1
|
|
5
|
+125≧
|
Within \12%
initial value |
Within12X original
limit |
See table 1
|
|
6 |
+25≧
|
Within \5%
initial value |
Within original
limit |
Within original
limit |
|
 |
|
 |
Temperature cycle |
|
|
|
-55≧,room
temperature,125≧ ,5 cycles 30min , Post test performance:
a. Capacitance---within
\5% initial value
b. DC Leakage---within initial limit
c. DF--- within initial limit |
|
 |
|
|
 |
Life test |
|
|
|
2000 hours
,+85≧,rated voltage or 2000 hours,+125≧,2/3 rated voltage, post test
performance:
a: Capacitance---within \10% initial value
b. DC Leakage---within 200% initial limit
c. DF--- within 150% initial limit
|
|
 |
|
|
 |
Surge
voltage
|
|
|
|
85≧,1.15
rated voltage measurement is done after 1000 cycles of 0.5 minutes on
5.5 minutes off with 1000 Ω of series resistance. Post test
performance:
a. Capacitance---within \10% initial value
b. Leakage---within initial limit
c. DF--- within initial limit |
|
 |
|
 |
Solvent
resistance |
|
|
|
Solution:
isopropyl alcohol, solution temp:20-25≧ .The specimen shall be
completely immersed in the solution for 1 min. and the marking shall
be rubbed with a brush 10 times. The above cycle will be applied 3
times and then the marking shall be examined visually. post test
performance:
a. Capacitance---within initial limit
b. DC Leakage---within initial limit
c. DF--- within initial limit
d. physical---Marking must be legible |
|
 |
|
|
 |
Solder ability
|
|
|
|
Solder temperature:230\5≧,immersion times
(solder):3\0.5sec, Immersion in flux 5-10sec, .The specimen shall be
immersed completely, post test performance:
The dipped portion of the termination is at least
95% covered by a new solder coating. |
|
|
|
|