¡ô
Operating temperature: -55¡æ
~ +125¡æ (above 85¡æ, use
dreaded voltage).
¡ô
Capacitance
Tolerance: ¡À20%£¬¡À10%
.
¡ô
Capacitance
Range: 0.1¦ÌF~330¦ÌF.
¡ô
Voltage
Rating£º4V~50V£®
¡ô
DC
leakage current(20):I0
¡Ü0.01CRUR or
0.5¦ÌA (whichever is
greater ) .
¡ô
Dissipation
factor (20¡æ): see table 1.
¡ô
Temperature
performance: see table 1.
¡ô
Climatic
category: 55/125/21.
¡ô
Life
test: 2000 hours.
¡ô
Reliability:2%
per 1000h at 85¡æ with 0.1¦¸/V
series impedance 60% confidence level.
 |
Table 1 |
| ¡¡ |
|
Cap.
(¦ÌF) |
Capacitance
Change£¨%£© |
Max
D.F (%) |
Max
DCL£¨¦ÌA£© |
-55¡æ |
+85¡æ |
+125¡æ |
-55¡æ |
+20¡æ
|
+85¡æ |
+125¡æ |
+85¡æ |
+125¡æ |
¡Ü1.0 |
-10 |
+15 |
+25 |
6 |
4 |
6 |
6 |
10
I0 |
12I0 |
|
1.5-68 |
-10 |
+15 |
+25 |
10 |
6 |
10 |
10 |
10
I0 |
12I0 |
|
100-300 |
-10 |
+15 |
+25 |
12 |
8 |
12 |
12 |
10
I0 |
12I0 |
|
¡Ý470 |
-10 |
+15 |
+25 |
16 |
12 |
16 |
16 |
10
I0 |
12I0 |
|
 |
¡¡ |
|